济南油烟净化器在工作中经常会出现一些故障。比如高压电场跳闸保护等。一些非技术性的故障问题我们可以通过检测判断故障原因,来自己进行解决。下面就为大家详细介绍这个故障的相关信息。
Jinan oil fume purifier often has some faults in its work. Such as high voltage electric field trip protection. We can solve some non-technical fault problems by detecting and judging the fault causes. The following will give you detailed information about this fault.
(1)电场短路
(1) Electric field short circuit
故障原因:①在安装时不小心使阴极针歪。②在清洗后电场内残留有杂物。
Fault cause: ① the cathode needle is crooked due to carelessness during installation. ② Sundries remain in the electric field after cleaning.
解决方法:①拆下电场,校正阴极针。②电场内的杂物。
Solution: ① remove the electric field and correct the cathode needle. ② Remove sundries in the electric field.
(2)绝缘子短路
(2) Insulator short circuit
故障原因:清洗时绝缘子上残留有过多的清洗剂。
Fault cause: too much cleaning agent remains on the insulator during cleaning.
解决方法:将绝缘子清洗干净。
Solution: clean the insulator.
(3)高压变压器损坏
(3) High voltage transformer damaged
故障原因:听不到静电声,检查电场没有短路,而且一开机即跳闸或烧保险管。
Fault cause: no static sound can be heard. Check that there is no short circuit in the electric field, and it trips or burns the fuse tube upon startup.
解决方法:更换高压变压器。
Solution: replace the high-voltage transformer.
(4)变压器超温
(4) Transformer overtemperature
故障原因:由于厨房环境温度过高,通常是设备工作到高峰时跳闸。
Fault cause: due to the high ambient temperature in the kitchen, the equipment usually trips at the peak of operation.
解决方法:引入鲜风对油烟净化设备进行强制降温。
Solution: introduce fresh air to forcibly cool the oil fume purification equipment.
(5)可控硅损坏
(5) Thyristor damaged
故障原因:此故障表现为电场只放电一次就跳闸保护或烧保险管。
Fault cause: this fault is shown as tripping protection or burning of fuse tube when the electric field is discharged only once.
解决方法:更换相同型号的可控硅。
Solution: replace the thyristor of the same model.
油烟净化器出现的高压电场跳闸保护故障原因解决就是上述所讲解的内容这样了,当然如果您在使用之前提前做好了预防措施,那么后期就会很少出现问题了,更多内容就来我们网站
http://www.jnqsg.com咨询吧。
The reason for the high-voltage electric field trip protection fault of the oil fume purifier is the content explained above. Of course, if you take preventive measures in advance before use, there will be few problems in the later period. For more information, please visit our website http://www.jnqsg.com Consult.
上一篇:通风管道安装过程中振动和噪音的预防